Specifications

Package: Software on CD, hardware A/D converter (internal PCI, external USB or external TCP/IP for network), hardware key, detector and trigger cables, manual and mousemat.

System configuration: Any 32-bit Windows system (98, Me, NT, 2000, XP)

Recommended configuration for Win 2000/ XP: PC Pentium/900 MHz, 256 MB RAM, monitor 1024x768, 64K colors (16 bit High Color), CD ROM, free PCI slot/USB connector for A/D converter.

Minimal configuration for Win 98: PC Pentium/200 MHz, 32 MB RAM, monitor 800x600, 256 colors, CD ROM, free PCI slot/USB connector for A/D converter.

Number of instruments/channels: Up to 4 chromatographs (instruments) at a time, each up to 4 detectors (channels). 1 chromatograph (instrument) - 1 time base Supported chromatographs: Any detector with voltage output, up to 30m distance Measuring ranges: Bipolar: 156, 1 250, 10 000 mV, integration frequency up to 100 Hz, 24-bit resolution GLP/ 21 CFR Part11 requirements:

Password protection

Password expiration

Electronic signature

Audit trails

User account with access rights

Interface with auto samplers: The station interfaces with all auto samplers (as a slave or master), direct control available (refer to the list of controlled instruments) of some auto samplers.

Integration: Separate integration table for every detector, 27 integration parameters (peak width, threshold, tangent slope ratio etc.), integration parameters programmable in time, automated reintegration.

Calculation types: Both without and with calibration (internal and external standard method), parameters of individual peaks for assessing efficiency of the column and the chromatographic system as a whole, SST Module for establishing deviations and reproducibility of some selected parameters.

Calibrations: 6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks) Work with chromatograms: Overlay, mathematical operations with chromatograms, custom labels and settings for chromatograms.

Automation: Sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – Post Run, Batch.

Presentation of results: Integrated customisable table of results, columns with user-defined calculation, summary table, and export in text or database format.

Custom calculations: 12 predefined mathematical operators, 15 basic and 4 summary functions.

Protocol: Custom protocols, print preview option Data export: ASCII, AIA, dBase Data import: CSW17, CSW32, ASCII, AIA.

Multi-user environment: Selectable system of user accounts with independently customisable parameters and appearance for individual users.

Network environment: Easy off-line (at the file level) data sharing among all stations in a local network Add on modules.

Extensions:
Instrument and auto sampler control modules,
GPC software,
Test IQ,
Validation Kit,
SST Module,
Clarity Evaluation software (off-line version for reprocessing on another PC),
LIMS Interface,

Support, warranty,
Automatic software update from Internet,
Free software updates,
Free access to knowledge database,
Online technical support,